Showing results: 646 - 660 of 1251 items found.
-
Ducommun Inc
Ducommun's frequency converter families include waveguide detectors (FAS), passive and active multipliers (FMP and FMA), up and down converters (FUB and FDB), harmonic mixers (FDH), subharmonically pumped up and down converters (FUS and FDS) and phase detectors and single sideband modulators (FPB and FSS). These devices are offered in 7 waveguide bands to cover entire 18 to 110 GHz frequency spectrum. These converters employ high performance GaAs Schottky beamlead diodes and DLT's proprietary circuit configuration to produce superior performance, such as low conversion loss and up to full waveguide instantaneous operation bandwidth.
-
782510-01 -
NI
The NI‑5791 provides continuous frequency coverage from 200 MHz to 4.4 GHz. It features a single-stage, direct conversion architecture that provides high bandwidth in the small form factor of a FlexRIO adapter module. The onboard synthesizer, which is the local oscillator (LO), sets the center frequency for acquisition and generation, and you can export it to other modules for multiple input, multiple output (MIMO) synchronization. You can also import the LO from an external connector, enabling synchronization of up to eight NI‑5791 modules. For higher frequencies or a greater number of devices, you can use an external LO distribution amplifier.
-
E9304A -
Keysight Technologies
Refer to the E9301A for standard power sensor features Low frequency coverage (9 kHz to 6 GHz) for EMC/EMI test applications such as the radiated immunity test (IEC61000-4-3)High sensitivity (-60 to +20 dBm) and fast measurement speed to reduce the time taken to calibrate radiated field uniformity and EMC/EMI test receivers Measure transmitter power and receiver sensitivity at Very Low Frequency (VLF) to microwave frequencies Special option available to 18 GHz Compatible with EPM (new N1913A/ 14A, E4418B/ 19B), EPM-P (E4416A/ 17A) and P-series (N1911A/ 12A) power meters
-
TG2000 Series -
Aim-TTi
0.001Hz to 10MHz/20MHz frequency range6 digits or 1mHz resolution1ppm stability and 10ppm one year accuracyLow distortion, high spectral purity sine wavesInternal phase continuous sweep, lin or logAM, FSK, gated and tone switching modes5mV to 20V pk-pk from 50 or 600 OhmsStorage for multiple instrument set-upsUSB and RS232 Interfaces (TG2000 only)
-
DP-16K Series -
PINTEK Electronics
*High Frequency Performance Model*Bandwidth:(-3 dB)**DC~100 MHz (DP-16K)**DC~70 MHz (DP-16KM)**DC~50 MHz (DP-16KL)*2 Range: x100, x1000*Input Impedance:**10 MΩ // 10 pF each side to ground*Over Range Indicate LED*Rise Time: 4 ns
-
MT985 Series -
Maury Microwave Corporation
Maury''s MT985AL01 LXI controlled automated tuners are optimized for a broad class of in-fixture and on-wafer applications requiring flexibility, broad frequency coverage and ease of use. Based on Maury''s proven non-contacting probe technology, these high-performance tuners evolve beyond outdated contacting probe technology to deliver high VSWR with superb accuracy and reliability.
-
HF (13.56 MHz) -
Balluff GmbH
BIS M uses the high frequency (HF) 13.56 MHz and supports the standard according to DIN ISO 15693 and 14443. Communication modules/gateways are used for the point-to-point or bus linking and are directly connected to a serial interface of a PC/a bus interface. The Subnet16 TM bus architecture supports a subnet of up to sixteen nodes via an RS485 interface.
-
SV-10 Series -
A&D Company, Ltd.
Newly developed Tuning-fork Vibration Method* promises you high accuracy and wide measurement range without replacing sensor plates!! *Patent pending. Sine-wave Vibro Viscometer SV-10/SV-100 measures viscosity by detecting the driving electric current necessary to resonate the two sensor plates at constant frequency of 30Hz and amplitude of less than 1mm.
-
MAG Serie -
Macintyre Electronic Design Associa
The µMAG series is the premiere, handheld instrument for the precision measurement of the vector components of weak static and low frequency magnetic fields. The superior stability, linearity and accuracy of the uMAG, compared to Hall Effect or Magnetoresistance base instruments, make it the only choice for high quality low magnetic field measurements and best choice for gerneral purpose magnetometer applications.
-
K&L Microwave
K&L Microwave offers a variety of Tunable Filter Products to satisfy a broad range of filtering applications. Tunable Bandpass and Bandreject filters provide the best solution for pre-tuning desired signals while rejecting interfering signals. Mechanically-tuned, high Q cavity filters typically allow center frequency to be tuned over at least one octave.
-
Alpha Lab, Inc.
This meter measures AC electric field in the vertical direction (same direction as the long axis of the meter). It has a wide frequency range (40 Hz - 20 KHz) and high accuracy (+/-2% of reading +/- 1 count) with an electric field strength range of 19 999 V/m and resolution of 1 V/m. The sensor is in the top 1/3 of the meter.
-
MCL-4000F -
MULTI MEASURING INSTRUMENTS Co., Ltd.
*3CT method enabled easy AC leakage current measurements with simple clamping of each phase conductor by 3 CTs or 4 CTs.*Use 4 CTs for 3phase/4wire power system.*Load current measurements for each phase conductor up to AC 800A.*Filter rejection for high frequency noise.*DC mV output for recorder.
-
4B Components Ltd.
4B has a wide range of radio frequency (RF), rotary paddle and capacitance point level indicators for detecting high, intermediate, or low levels of liquids, powders and free flowing granular solids stored in tanks, bins, silos or other containers. Certain units can also be used as plug or choke detectors in chutes, conveyors and elevator legs.
-
FEINMETALL GmbH
FEINMETALL offers a wide range of contact probe:ICT / FCT probes, short travel probes, double plunger probes, fine pitch probes, interface probes, wire harness probes, threaded probes, high current probes, switch probes, twist proof probes, push back probes, koaxial probes, radio frequency probes.
-
Insight Product Company
Insight Product Company offers a high-power synthesizer of pulsed signals. They are ideal for ESR, EPR, and DNP experiments. The synthesizer has a high frequency stability (10-6), and allows control over the duraction and begining time of pulses. The synthesizer also enables phase manipulation, where each pulse is shifted by 90 or 180 degrees relative to the previous pulse.